This documentation is still very early and not complete nor well written.
logo
Pack+ V
Battery V
Battery A
Event
Action
39.189
39.720
0.750
Charger unplugged
Unplug
39.220
39.730
0.610
Charger unplugged
Unplug
39.209
39.740
0.520
Charger unplugged
Unplug
39.209
39.759
0.450
Charger unplugged
Unplug
39.220
39.750
0.400
Charger unplugged
Unplug
39.230
39.759
0.360
Charger unplugged
Unplug
39.220
39.750
0.300
Charger out of current.
Nothing
39.240
39.680
0.020
Nothing happens
Unplug & plug
All actions to unplug charger have been detected.
Each time, the charge algorithms stops, and restart when charger gets plugged back.
End of charge happens when charger is out of current.
Unplug & plug back charger after end of charge doesn’t turn battery to charge !
💡
Everything works as expected.