This documentation is still very early and not complete nor well written.
logo
Charger stops giving voltage in rebalance mode after 30-200s.
Is this a charger protection triggered ?
Protections
Argue
Conclusion
Timing
Maybe.
Maybe
Switching off
?
Maybe
OT
IC is 60Β°C
Maybe
OC
No current is drawn.
No
OV
Battery is in voltage range. 40-42V
No
SC
No SC is detected
No
Reverse Pol
Fets are OFF. Should not happen
No
Precharge CC-CV
No current flows. Back or forward.
No
Recharge
No current flows. Back or forward.
No
N
CHG s at entry
Valid current
CHG s at leave
CHG lasts
Rebalance lasts
Exit reason
Exit from
Notes
1
42
2.14
4819
4775
44
Unplug
Rebalance
2
4824
1.35
6518
1694
64
Unplug
Rebalance
3
6523
1.32
6750
227
64
Unplug
Rebalance
4
6778
1.32
7069
291
220
Unplug
Rebalance
5
7071
None
7076
5
None
No valid current
Charge And Balance
6
7079
1.37
307
7386
205
Unplug
Rebalance
7
7397
1.37
240
7637
157
Unplug
Rebalance
8
7651
None
7656
5
None
No valid current
Charge And Balance
9
7877
1.35
8097
220
168
Unplug
Rebalance
10
8100
1.35
8223
123
72
Unplug
Rebalance
11
8243
None
8248
5
None
No valid current
Charge And Balance
12
8259
1.53
8437
178
140
Unplug
Rebalance
13
8443
1.56
8527
84
41
Unplug
Rebalance
14
8532
1.56
8711
179
157
Unplug
Rebalance
15
8724
None
8729
5
None
No valid current
Charge And Balance
16
8732
1.54
8799
67
22
Unplug
Rebalance
17
8842
1.57
8914
72
44
Unplug
Rebalance
18
8927
1.56
8985
58
35
Unplug
Rebalance
19
None
5
None
No valid current
Charge And Balance
20
9039
1.54
9152
113
85
Unplug
Rebalance
21
9157
1.56
9450
293
266
Unplug
Rebalance
22
9481
10095
614
166
Unplug
Rebalance
2 RB
23
10100
1.54
10328
228
169
Unplug
Rebalance
24
10356
1.56
10505
149
739
Unplug
Rebalance
25
13254
None
13259
5
None
No valid current
Charge And Balance
26
15696
None
26843
11147
10374
Unplug
Final-balance
It’s FB
27
30072
None
45347
15275
14578
Unplug
Final-balance
It’s FB
28
48354
None
48359
5
None
No valid current
Charge And Balance
πŸ’‘
Slow progressive current. Valid current is well detected.
Image without caption
πŸ’‘
Slow drop then rise current. Valid current is well detected.
Image without caption
πŸ’‘
Current with spike and drop. Valid current is well detected.
Image without caption
πŸ’‘
No current at all for 5s. Inalid current is well detected.
Image without caption

The battery FSM entered 3 times in Final Balance. Next graphs show data from the charge enter to final balance enter. We see the CV phase, correctly detected.
Image without caption
Image without caption
Image without caption
Share