This documentation is still very early and not complete nor well written.
logo
Time
Cell 0
Cell 1
Cell 2
Cell 3
Cell 4
Cell 5
Cell 6
Cell 7
Cell 8
Cell 9
Battery V
Battery A
Load
SoC
State
Comments
6,1
4,086
4,09
4,09
4,088
4,063
4,091
4,092
4,088
4,09
4,092
40,68
-0,020
41,280
82,890
Idle
8,6
4,132
4,13
4,137
4,126
4,099
4,111
4,125
4,118
4,129
4,206
41,120
-0,830
41,200
82,890
Charge (Charge-and-balance)
11,0
4,186
4,179
4,192
4,17
4,143
4,136
4,164
4,153
4,174
4,301
41,620
-1,730
41,070
82,900
Charge (Charge-and-balance)
13,5
4,088
4,093
4,094
4,091
4,066
4,094
4,094
4,091
4,093
4,096
40,720
-0,020
41,270
82,920
Error
cellOverVoltage
16,0
4,086
4,091
4,091
4,089
4,064
4,092
4,092
4,089
4,091
4,092
40,680
0,000
39,730
82,920
Error
cellOverVoltage
18,5
4,086
4,09
4,091
4,089
4,063
4,092
4,092
4,089
4,091
4,091
40,690
-0,010
40,140
82,920
Charge (Charge-and-balance)
21,0
4,086
4,09
4,09
4,089
4,063
4,092
4,092
4,089
4,091
4,091
40,680
0,010
40,140
82,920
Charge (Charge-and-balance)
Charger has not enough current
23,4
4,087
4,091
4,092
4,089
4,064
4,092
4,093
4,089
4,092
4,094
40,710
-0,040
41,270
82,920
Idle
Image without caption
💡
With a slowly unbalanced cell, and a 80% charged battery, we have a big voltage spike when opening the FETs. This triggers an COV, which puts battery in ERROR. The FETs are closed, it goes back in CHARGE, FETs are opened back but current doesn’t seems to be drained (Last 3 columns).
Share