Image without caption
Battery leaves charge state with from balance-only state with Battery is balanced condition. Cell voltages are:
c++
Cell 0: 4.141000 V Cell 1: 4.150000 V Cell 2: 4.156000 V Cell 3: 4.148000 V Cell 4: 4.181000 V Cell 5: 4.181000 V Cell 6: 4.156000 V Cell 7: 4.161000 V Cell 8: 4.151000 V Cell 9: 4.153000 V
There is still a 0.04 V difference, BQ should have kept balancing cells as we ask him to stop at 0.02 V difference. Referring to an OCV curve, there is a 90 mAh difference between Cell 0 and Cell After this, it goes in Idle and never balance again.