This documentation is still very early and not complete nor well written.
logo
💡
With a little unbalancing, the 42V charger stop giving enough current, and battery goes to Final Balance. Soc is 98.51% at end of charge with 41.599998V battery.
Image without caption
FSM logs

Just after a simple reboot, we got this. The test was stopped before the end of the charge.
Image without caption
FSM logs

Two days later, after waking & charging the battery, we get:
Image without caption
FSM logs
It goes in Final Balance then leave charge when fully balanced.
Cell9
Time (s)
Tension (V)
Capacity (mAh)
Intensity (mA)
P1
2000
4.189
3281
P2
5000
4.182
3265
Delta
3000
0.007
16
19.2
💡
Charge flow is good. Only thing: balancing current of 19.2A seems pretty low than expected 50mA .