This documentation is still very early and not complete nor well written.
logo
Image without caption

Cell voltage comparison

Balancing config here is :
c++
{ .maxDischargeCurrent = 1, .balancingCheckInterval = 5, .minimumCellVoltage = 3.5, .cellImbalanceDeltaStart = 0.020, .cellImbalanceDeltaStop = 0.010, .simultaneousCells = 5 };
Event
Highest Cell ID
Highest Cell V
Highest Cell mAH
Lowest Cell ID
Lowest Cell V
Lowest Cell mAH
Delta V
Delta mAh
Before discharge
C6 C7 C8
4.195
3295
C1
4.170
3239
0.025
56
After discharge & relax time
C3 C8
3.464
656
C1
3.455
638
0.09
18
Before 1st balancing in charge
C6 C7 C8
4.195
3295
C1
4.171
3241
0.024
54
End of charge & relax time
C6 C7 C8
4.180
3261
C1
4.163
3223
0.017
38
C1 Ω: 20.40 C6 Ω: 20.12 C7 Ω: 20.40 C8 Ω: 20.19
FSM logs

Discharge phase

Duration: ~32 minutes (~1907 s).
Image without caption
FSM logs

Relax phase

Duration: ~36 minutes (~2159 s).
Image without caption
No FSM logs

Charge phase

Duration: ~320 minutes (19196s).
Image without caption
FSM logs